GB INSTALLATION
INSTRUCTIONS
1
WARNING. It is recommended to
install the video handset in a dry
place.
WALL MOUNTINGS
XKP/300+XKP/85
Set the embedding box (three-
module version, or round with 65
mm) so that it is flush with the wall
at an appropriate height for the
user. Join the mountings using the
two joints, figure 2, and insert the
two rectangular hole plugs on the
outer sides, figure 1.
Remove the connecting cable
connector
mounting slot and pass it through
the relevant hole towards the
XKP/85 mounting, figure 2.
Fix the mounting to the wall by
means of provided retainers and
screws, figure 3, 4 and 5.
6
Having made the connections,
position the wires so that they do
not pass over the XKP/300 moun-
ting's lower fastening screws.
XV/200 (XVC/200) MONITOR
MODULE WITH XC/300
HANDSET MODULE
Make sure the locking latch is in
the left position
Insert the monitor module on the
XKP/300 wall mounting and insert
it on the actual support by pushing
downwards, figure 6.
In order to prevent the module
from falling subsequent to acci-
dental knocks, secure it to the
mounting by moving the locking
latch to the right, figure 6.
Pass the monitor module connec-
ting cable through the opening in
the base of the handset module,
figure 7.
Insert the base on the XKP/85
mounting and insert it on the
actual
support
downwards, figure 8.
7
Secure the base in place using the
screw supplied and make the con-
nection between the modules,
figure 8.
Fit the handset module housing
and apply the two side panels,
figure 9 and 10.
Insert the cable connector of the
receiver in the base and hang up
the receiver, figure 11 and 12.
• Dimensions: 239x224x74 mm.
WARNING. The use of the monitor
module alone, in system 300
installations, is possible in combi-
nation
with
coder/decoder for video receivers,
or telephone interface IT/300.
WALL MOUNTING XKP/300
Set the embedding box (three-
module version, or round with
65mm) so that it is flush with the
wall at an appropriate height for
the user. Insert the two rectangular
hole plugs on the outer sides of
the mounting, figure 13.
Fix the mounting to the wall by
8
means of provided retainers and
screws, figure 14, 15 and 16.
XV/200 (XVC/200)
MONITOR MODULE
Make sure the locking latch is in
the left position
Insert the monitor module on the
XKP/300 wall mounting and insert
it on the actual support by pushing
downwards, figure 17.
In order to prevent the module
from falling subsequent to acci-
dental knocks, secure it to the
mounting by moving the locking
latch to the right, figure 17.
Apply the two side panels, figure
18 and 19.
• Dimensions: 154x224x52 mm.
from
the
XKP/300
FUNCTION OF EACH TERMINAL
Support XKP/300
Terminal block M1
B line
Terminal block M2
12V AC 14÷18V DC
monitor module supply voltage
XC/300 handset modul
B line
landing call
−
ground
, figure 6.
Jumper SW1
Normally supplied ready inserted.
Remove the jumper in the event
the volume of the call note is to be
attenuated.
Function of jumpers SW1 and
SW2 of board XKP/300
SW1: normally supplied ready
inserted (ON). The function and
position are indicated in the units
for which their use is required.
SW2: normally supplied inserted
in the XC position (monitor modu-
le switched on by means of
XC/300 module). It must be inser-
by
pushing
ted in the XT position when the
monitor module is combined with
telephone module XT/200.
Function of jumper SW3 of
board XKP/300-1
Normally supplied ready inserted
(ON) to apply the end-of-line clo-
sing resistance.
Remove the jumper if the line con-
tinues.
The slow blow protection fuse F2 -
T 500 mA - is located on XKP/300
printed card.
(Fuse: F=fast, T=slow).
the
XCD/300
WARNING. When the monitor
module XVC/200 is installed on
the XKP/300 mounting, fuse F2,
type T 500 mA, must be replaced
with fuse type T 630 mA supplied
with the module.
Technical features
• Supply voltage: 12V AC or
14÷18V DC (from a transformer
installed near the monitor or direc-
tly from power supplier XA/300LR).
• Current demand with monitor on:
70 mA.
, figure 17.
3