Gb Installation Instructions; Product Description - Bpt b-red VRW2 Serie Manual Del Usuario

Tabla de contenido

Publicidad

norme vigenti e privilegiando il rici-
claggio delle sue parti costituenti.
Sui componenti, per cui è previsto
lo smaltimento con riciclaggio, sono
riportati il simbolo e la sigla del ma-
teriale.
GB INSTALLATION
INSTRUCTIONS
2-WIRE VIDEO ENTRY CONTROL
KIT VKW200
WARNING
FOR THE INSTALLER
These instructions must remain at-
tached to the receiver.
Attention.
Before installing the equipment,
carefully read the "SAFETY WARN-
INGS" contained in the package.
SAFETY WARNINGS
Read the following warnings care-
fully as they provide important in-
structions regarding the safe use,
installation and maintenance of the
equipment.
• After having removed the packaging,
make sure that the equipment is intact.
• The system must be installed in com-
pliance with current safety Standards.
• To avoid injury, the equipment must
be secured to the wall according to
the installation instructions.
• An omnipolar switch, with con-
tacts separated by at least 3mm,
must be installed upstream from
the audio/video entry control sy-
stem.
Technical features
VRW2* video
entry control
from VPSW2 14
Power supply
VDC
Operating
from 0 °C to 35 °C
temperature
Ring tone
dual tone
Picture tube
B/W 4" (10 cm)
Camera
Led
Dimensions
195x210x57 cm
* Possibility to connect an auxiliary contact (max 100 mA, 24 V)
** Possibility to connect impulse or continuous electric locks (12 V AC or DC
0.5A).
The delayed protection fuse of 630 mA is located on the printed circuit of the
power supplier.
4
• The equipment must not come
into contact with any liquid mate-
rial.
• Do not obstruct ventilation slots.
• Before connecting the equip-
ment, make sure that the rating
plate data corresponds to that of
the distribution network.
• This equipment should, like all the
system equipment, be used only for
the purpose it was explicitly designed
for; any other type of use is improper
and dangerous.
• The manufacturer is exempt from
any liability or damage as a result of
improper, incorrect or unreasonable
use of this equipment.
• Before performing any cleaning or
maintenance to the device, discon-
nect the power supply by opening
the system switch.
• In case of failure and/or malfunction
of the devices, disconnect them from
the power supply and do not tamper
with them.
• Should the device require repair, con-
tact a manufacturer-authorized tech-
nical service centre only.
• Failure to comply with the above
instructions may compromise the
equipment's safety.
• The installer must make sure that
the information for the user, where
applicable, is present on the devi-
ces.

PRODUCT DESCRIPTION

The video entry control kit for single
family homes is composed of:
VRW2
video entry control
VEPW2
entry panel
VPSW2
power supply
VRW2 video entry control
The video entry control unit is com-
posed of a wall-mounted unit equipped
with a receiver and monitor (fig. 1).
Entry panel
Power source
VEPW2
VPSW2**
230 V AC +6% -
10%, 50/60 Hz 10
VA
Output 14 V DC
from
-15°C
to
from 0 °C to 35 °C
+50°C
B/W Standard Vid-
eo CCIR (EIA)
IR for night-time
illumination
Low-profile 3-unit
model, for instal-
95x170x28.5 cm
lation on DIN rail
(fig. 16)
VEPW2 entry panel
The video entry control panel is a wall
mounted unit that features a double
call button that activates the same ex-
tension (fig. 1). A green LED illuminates
the button.
A sound confirms a received call.
The panel is composed of:
- A camera that can be manually ori-
ented, both horizontally and vertically,
by ±14° (fig. 2), with a fixed focus lens
(for dimensions of the area of coverage
see fig. 3);
- Green LED;
- Two potentiometers for the following
functions: 4):
P1 ( ), to adjust the volume of the vid-
eo entry control;
P2 ( ), to adjust the volume at the
entry panel.
It is possible to connect the video
entry control panel to a solenoid lock
maintained by a continuous flow of
current or one controlled by an im-
pulse generating equipment (12 V AC
or DC 0.5 A).
It is best to install the panel in a shel-
tered area to avoid direct rain or drip-
ping.
VPSW2 power supply
This consists of an AC/DC converter,
which is electronically and thermally
protected against overloads and short
circuits.
It provides continuous stabilized volt-
age of 14 V DC.
A single power supply is provided for
systems connected to the terminal + e
– of the video entry control.
INSTRUCTIONS FOR ASSEMBLY
VRW2 video entry control
Fix the socket directly to the wall (fig.
5), or in the built-in box (fig. 6 or fig. 7)
using the provided screws and plugs.
If the cables arrive from a duct outside
the wall, run the cable through at the
arrows as shown in figure 8.
Avoid excessive tightening of screws
on walls that are not perfectly flat.
Connect (see you "INSTRUCTIONS FOR
CONNECTION") and place the video
entry control on the metal socket as
indicated in figure 10.
To remove the unit from the bracket
use a screwdriver in the slot of the
cabinet (see fig. 11).
VEPW2 Entry panel
Unscrew blocking screws and disas-
semble plate from base (fig. 12).
Remove the cable-grip plate (fig. 13).
ATTENTION. The connection cables
must be inserted through the pro-
vided cable passages (fig. 14).
Fix the base to the wall using the
provided screws and screw anchors
(fig. 15).
Connect (see you "INSTRUCTIONS FOR
CONNECTION") and replace cable-grip
plate.
Before assembling the plate insert the
upper part into the head and then
tighten blocking screws (fig. 16).
VPSW2 power supplier
The unit can be installed in boxes with
DIN rail (EN 50022).
For overall dimensions see fig. 17.
The unit can also be installed against
the wall using the two provided plastic
tabs (fig. 18).
INSTRUCTIONS FOR CONNECTION
WARNING
Do not open or tamper with the
units; there is high voltage inside.
For connections, refer to the diagram
in figure 21 (BASIC CONFIGURATION).
Functions of terminals of VRW2
video entry control (fig. 9)
L–
data line negative
L+
data line positive
power supply negative
+
power supply positive
AUX
auxiliary services 100mA
AUX
Function of terminals of VEPW2 en-
try panel (fig. 4)
L–
data line negative
L+
data line positive
connection
solenoid lock
Function of terminals of VPSW2
power supplier (fig. 19)
230V
mains input
current output
14V
+
continuous stabilized
INSTRUCTIONS FOR THE USER
In case of damage, modifications
or interventions on system devices
(power supply, etc.) request help
from specialized professionals.
VRW2 Video entry control
The unit has three buttons for the fol-
lowing controls (fig. 1):
Door lock release
Entry panel activation
1
Auxiliary services (
)
And of the following controls (fig. 1):
Brightness control
Contrast control
Call volume control
1
(
) The auxiliary services control can be
used to activate, by means of suitable
devices that are not included in the
kit, auxiliary functions such as stairway
lights, additional openings and relays
at low voltage.
A call from the external unit is charac-
terized by a two-tone sound.
VEPW2 Entry panel
In order to write your name on the
label, extract the label cover first, then
the label (fig. 20).
DISPOSAL
Do not litter the environment with
packaging material: make sure it is
disposed of according to the regula-
tions in force in the country where the
product is used.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B-red vkw200B-red vepw2

Tabla de contenido