JAC TRADILEVAIN TL40 Manual Del Usario página 15

Ocultar thumbs Ver también para TRADILEVAIN TL40:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
Setting P1: Selects the display language.
Setting P2: Selects the unit of temperature.
Setting P3: Corrects any difference between the actual temperature of the sourdough starter and
the temperature shown on the display. For instance, if the measured temperature of the starter is
12°C and the temperature displayed is 15°C, replace the value of this setting (it will be 15 in this
case, since it is the value displayed) with the measured temperature, 12°C in this case.
Setting P5: Determines how many degrees above the setpoint the temperature at which the
cooling unit starts up will be. For instance, if you are in storage cycle 1 (12°C) and this setting is at
1°C then the cooling unit will start up when the sourdough starter temperature reaches 13°C
(12°C + 1°C).
Setting P29: Stops fast stirring cycles for a duration determined by this setting before feed time
(setting P37). For instance, if setting P37 is 08:00 and this setting is 01:00 then fast stirring cycles
will end at 07:00.
Setting P30: Sets the delay before the Tradilevain buzzes (lid open, fault, etc.). For instance, if
this setting is 5, the Tradilevain will not buzz until 5 seconds after the lid is opened.
Setting P31: Sets the duration of feed reminder buzzer.
Setting P34: If this setting is YES, stirring cycles will be stopped when switching to the storage
cycle.
Setting P35: Minimum storage temperature if setting P33 is YES.
Setting P44: Specifies the sourdough starter working capacity for the calculator function.
15
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tradilevain tl105Tradilevain tl220

Tabla de contenido