SPECIFICATIONS
POWER SUPPLY
LIQUID TEMP. RANGE
DISCHARGE
SUCTION
WATER LEVEL
INSTALLATION
WARNING: ELECTRICAL SAFETY Capacitor voltage may be hazardous. To discharge the motor capacitor, hold the
insulated handle screwdriver BY THE HANDLE and short capacitor terminals together. Do not touch the metal
screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
CAUTION: Do not touch an operating motor. Modern motors are designed to operate at high temperatures. To avoid
burns when servicing the pump, allow it to cool for 20 minutes after shut-down before handling.
Do not allow pump or any system component to freeze.
To do so will void warranty.
Pump water only with this pump.
Periodically inspect the pump and system components.
Wear safety glasses at all times when working on pumps.
Keep the work area clean, uncluttered and properly lighted; store properly all unused tools and equipment.
Keep visitors at a safe distance from the work areas.
WARNING: The pump body may explode if used as a booster pump unless a relief valve capable of passing full pump
flow at 75 psi is installed.
SHALLOW WELL JET PUMP INSTALLATIONS
Have a vertical depth between the pump and the water being pumped of 25 ft. or less
Have one pipe from the well to the pump case
Can be installed in a bored or drilled well, or in a driven well
REPLACING AN OLD PUMP
WARNING: Hazardous voltage. Disconnect power to the pump before working on a pump or a motor.
Drain and remove the old pump. Check the old pipe for scale, lime, rust, etc., and replace it if necessary.
Install the pump in the system. Make sure that all pipe joints in the suction pipe are air-tight as well as water tight. If
the suction pipe can suck air, the pump will not be able to pull water from the well.
Adjust the pump mounting height so that the plumbing connections do not put a strain on the pump body. Support
the pipe so that the pump body does not take the weight of piping or fittings.
You have just completed the well plumbing for your new shallow well jet pump. Please go to discharge pipe and
tank connections section.
WELL POINT (DRIVEN POINT) INSTALLATION
Drive the well, using drive couplings and a drive cap. Drive fittings are threaded all the way through and allow the
pipe ends to butt against each other so that the driving force of the maul is carried by the pipe and not by the threads.
The ordinary fittings found in hardware stores are not threaded all the way through the fitting and can collapse under
impact. Drive fittings are also smoother than standard plumbing fittings, making ground penetration easier.
115V/230V,60HZ,20/10Amp circuit
32°F to 77°F (0°- 25°C)
1in. FNPT
61013/61023/61033:1-1/4 in. FNPT
60013/60023/60033/62013/62023/60043/62043:1 in. FNPT
25 ft.
4