IMPORTANT ADVICE REGARDING THE
INSTALLATION
Other than that described in this documentation, you are also
- No. 10683
installation requirements
- No. 9615/90
- No. 10412:2 - hot water heating systems.
ded with residential solid fuel burning applian
ces and combined boiler, not exceeding a total
nominal heat input of 35 kW.
- Before carrying out any assembly it is important to verify
compatibility of the appliance, as stipulated in UNI 10683
- When assembly is completed, the installer must implement
"start-up operations" and issue documentation as required
- The connections, commissioning and veri cation of pro-
per operation of the thermo replace must be carried out
plumbing connections as required by UNI standards 10683,
assembly instructions.
after having been on for a couple of hours, before covering the
- pilasters, painting, etc.
are carried out, once the tests are completed successfully.
Consequently, EDILKAMIN does not accept responsibility for
expenses deriving from demolition as well as construction even
if either occurs as a result, after having replaced any damaged
EXTERNAL AIR INLET
An external connection with a 12,5 cm diameter crosssec-
tion throughout (refer to the technical table) is absolutely
necessary for the thermo replace to function properly and
is therefore imperative for this to be implemented.
This connection must link the air adjustment mechanism (E),
delivered separately. The mechanism, delivered separately,
Ensure that the points where there may be dispersion of air are
sealed well. The air adjustment mechanism (E) can be remo-
recommended to place a protection grille on the outer part of
the air inlet channel, however, ensure that this does not reduce
the cross-section. For distances longer than 3 m or with bends,
increase the given cross-section by a minimum of 10% to a ma-
level (it cannot enter from above).
E
INSTALLATION
CHIMNEY FLUES AND CHIMNEYPOT
suitable insulation.
The characteristics of the construction must be suitable to
cular reference to the mechanical resistance, insulation and the
gas tight sealing.
The fundamental characteristics of the chimneypot are:
- an internal cross-section at the base, which is the same as that
- an outlet cross-section which is no smaller than twice that of
- its position must be high enough to catch the wind and avoid
downdraft areas in turbulent wind.
In addition to that mentioned above, please consider the
indications stipulated in UNI 10683/2005 standard, para-
graph 4.2: "connection to the smoke outlet system" and its
subsections.
max.45°
-
E
- 25
-
1
45°
45°
3
-
-
2
NO
4