EdilKamin H2OCEANO 23 Instalación Uso Y Mantenimiento página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
IMPORTANT ADVICE REGARDING THE INSTALLATION
sonnel, who can implement all connections in accordance with
from complying with these instructions.
Compliance with regulations regarding the earth connec-
tion is fundamental for the safety of people.
It is obligatory to install a differential circuit breaker switch
before the device and the entire electrical circuit of the thermo
It is also obligatory to connect the pump, valve and metal parts
LEGEND
AA
acoustic alarm switch
R
way valve opening setting (KITS 1-3)
R
circulators operation setting (KIT 2)
RIC
internal pump setting
S
MAN-OFF-AUTO selector
SP
pump light
SS
overheating light
ST
temperature scale
SV
3-way valves light (KITS 1-3)
SV
circulators setting (KIT 2)
TECHNICAL DATA
Power Supply (+15 – 10%)
Degree of protection
Sensor range
Thermometer
Maximum contact rating of the circulator
Maximum contact rating of the 3-way valve
Fuse
The electric control regulator allows you to monitor the opera-
- MAN-OFF-AUTO selector (S)
- temperature scale (ST)
- acoustic alarm (AA)
- 3-way valve opening setting (R) (KIT1-3)
- circulators operation setting (R) (KIT2)
- internal pump setting (RIC)
- 3-way valve light (SV) (KIT1-KIT3)
- circulators setting light (SV) (KIT2)
- overheating pump (SS)
- pump light (SP)
ELECTRONIC REGULATOR
Vac 230
°C 0÷+50
mt 1,2
°C 30÷90
W 250
mA 500
OPERATION
- Control device:
-
- Protection device (acoustic alarm system):
This system intervenes when the water temperature exceeds
90° C and warns the user to stop adding fuel.
The acoustic alarm can be disabled from the switch (AA).
However, the alarm remains enabled by means of the overhe-
ating light (SS). To restore the initial settings, the switch (AA)
must be enabled after the water temperature in the thermo
Power supply device (circulation system):
The pump remains on when in manual mode and off when in
OFF mode. When in AUTO mode, the pump is activated by the
system when the desired temperature is reached, by means of
the internal setting (RIC), which ranges from 20 to 80° C (this
is pre-set at 20° C).
- Operation device (setting system):
operating light (SV) goes on.
the system opens the electrical circuit and the 3-way valve
Attention: During normal operation check that the warning
lights (SV) and (SP) are lit.
POSITIONING
The electronic regulator must be installed close to the thermo
The sensor must be immersed in the well.
INSTALLATION
The power supply must be disconnected from the mains
and the AUTO-OFF-MAN selector (S) must be in the OFF
position when all these operations are carried out.
Follow this procedure to install the electronic regulator cor-
it in place against the wall with the dowels supplied.
Then make the connections, paying utmost attention to the
wiring diagram and pass the wires through ducts that are in
conformity with the regulations in force. Put the cover back in
place and tighten the screw.
Connect the brown wire (phase) and blue wire (neutral) of the
3-way Valve, respectively, to terminals 5 and 6 of the regula-
Follow the assembly instructions contained in the package to
connect the regulator to the system properly.
- 34
-
-
-

Publicidad

Tabla de contenido
loading

Tabla de contenido