PLAN THE INSTALLATION
COOKING AREA
Do not install above or
inside this area.
o
45
NOT FOR USE IN
A COOKING AREA.
INSTALL HOUSING & DUCT
1. Bend
housing tabs.
Use a pliers to bend
housing TABS out to
90
0
.
2. Mount housing
to joist.
Hold housing in place
so that the housing tabs
contact the bottom of
the joist. The housing
mounts with four (4)
screws or nails. Screw
or nail housing to joist
through lowest holes in
each mounting flange,
then through high-
est holes. NOTE: Mounting to I-JOIST (shown) requires use
of SPACERS (included) between the highest hole of each
mounting flange and the I-joist.
CONNECT WIRING
5. Connect electrical wiring.
secure house wiring to wiring plate. Connect wires as shown in wiring diagrams.
o
45
Cooking
Equipment
Floor
TABS
SPACER
(use for mounting to I-Joist)
SPEAKER
Run 120 VAC house wiring to installation location. Use proper UL approved connector to
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
*Purchase
separately.
3. Attach
damper/duct
connector.
Snap damper /
duct connector
onto housing.
Make sure con-
nector is flush with
top of housing and
damper flap falls
closed.
4. Install 4-inch
round duct-
work.
Connect 4-inch round
ductwork to damper /
duct connector. Run
ductwork to a roof cap
I-JOIST
or wall cap. Tape all
ductwork connections
to make them secure
and air tight.
MODEL SPK110
OR
Seal duct
joints with
4-IN. ROUND
tape.
ELBOWS*
Page 3
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)

Publicidad