Holder:
Issued by:
Safety (CE-LVD) :
Safety (NRTL) :
Safety (SAA) :
EMC (CE) :
EMC (NRTL) :
Efficiency - BC
mark
(California
Energy Commision)
Energy usage:
IP rating
t° operating range -20°C <-> 40°C / -4°F <-> 104°F
Weight (packed)
Size without cable 220 x 70 x 90mm / 9.45" x 2.76" x 3.54"
Cable Length
Wall mount
Accessories
Reverse drain
Max input rating
Output volt range
Protection Input
Protection output
Design copyright
& trademark

PRODUCT INFORMATION

Certification / Conformity
TecMate (International ) S.A. , B-3300 Tienen, Belgium
TUV SUD Product Service GmbH, DE (Safety and EMC)
Low voltage directive 2014/35/EU; EN 60335-2-29:2004/A2:2010;
EN 60335-1:2012/A11:2014; EN 62233:2008
UL 1236:2015; CAN/CSA C22.2 no. 107.2-01 (R2011)
AS/NZS 60335.2.29:2004 Inc A1-2; AS/NZS 60335.1.2011 Inc A1
EMC Directive 2014/30/EU; EN55014-1 2006/A2:2011; EN55014-2
1997/A2:2008; EN61000-3-2:2014; EN61000-3-3:2013
FCC CFR Title 47 Part 15 Subpart B
CEC-400-2012-011-CMF; 10 CFR Section 430.23 (aa) Appendix Y to
Subpart B of Part 430.
Tests by: Mantek International Canada Inc, Oakville ON, Canada.
Listed models: TM29x
Not charging: P < 0.5W Long term maintenance: P < 0.5W ( < 0.012
kWh / day, < 4.4 kWh / year )
Mechanical
IP54
0.8kg (1.3kg) / 1.76lbs (2.87lbs)
Input: 180cm / 71" Output: 191cm / 75"
4 mount positions
O-01 Weatherproof battery cable; O-04 battery Clips.
Standard SAE connectors
Electrical (additional)
Id < 0.5mA
90 - 264Vac 47-63Hz
0.5V - 14.4V @ 5A
AC fuse: 3A 250V (non accessible)
AUTOMATIC: reverse polarity; no output if no battery is connected;
limited output current (1A max).
TecMate (International) S.A., B-3300 Tienen, Belgium