Ingeteam
6. Use the joystick to scroll to the SYS
system selection screen. Press the
joystick once (PRG will appear at the
bottom of the display). Move the joystick in
any of the 4 directions until you come to
1P (for single phase installations) or 3P.N
(for three-phase installations). Press the
joystick once to accept
7. For the A65+ wattmeter, scroll to the CT
RATIO transformer ratio selection screen.
For example, if the transformer primary
current is 3000 A and the secondary
current is 5 A, then the transformer ratio is
600
8. Use the joystick to scroll to the ADDRESS
node number screen. Press the joystick
once (PRG will appear at the bottom of
the display). Move the joystick in any of
the 4 directions to indicate the wattmeter
node number. This number must be the
same as the one indicated on the charging
point that will be communicating with the
wattmeter. (This number can be changed
through the webmanager. Further
information is available in the charging
point configuration manual). Press the
joystick once to accept
9. This gives you access to the BAUD RATE
configuration screen. Press the joystick
once (PRG will appear at the bottom of
the display). Move the joystick in any of
the 4 directions to select9600 bps. Press
the joystick once to accept