INGEREV SMART DLM

2 Power Management Systems

Ingeteam differentiates the follow power management capacities in its equipment:
-

Dynamic Load Management 2.0

-

SMART DLM 2.0

2.1 Dynamic Load Management 2.0
Dynamic Load Management 2.0, hereinafter DLM 2.0, is a power management system that is supplied
as standard in all the INGEREV charging point models.
DLM permits the joint power management of a number of charging points, ensuring that the joint
power threshold assigned is never exceeded, regardless of the number of vehicles connected to the
Charging Points.
The system is multi-master, so that any of the units can assume group management, with no special
equipment required.
The management is adaptive, amp by amp and in real time, based on the number of units in
operation, the type of socket used on each charger and the current demanded by each vehicle.
The maximum number of interconnected units is 30.
Access to, and configuration of the DLM 2.0 is made through the INGEREV® WEB Manager interface.
2.2 SMART DLM 2.0
SMART DLM 2.0 (or Floating-point Dynamic Power Management) refers to the capacity for the real-
time modification of the power setpoint of the DLM 2.0 system, based on the consumption measured
at a point of the installation, in order not to exceed the power defined at the said frontier point.