The following instructions should be read by a qualified
technician to ensure that the appliance is installed,
regulated and technically serviced correctly in compliance
with current regulations.
Important: disconnect the cooker from the electricity when
making any adjustement, maintenance operation, etc.
Installation of the cooker
The appliance can be installed next to furniture units which
are no taller than the top of the cooker hob. The wall in
direct contact with the back panel of the cooker must be
made of non-flammable material. During operation the
back panel of the cooker could reach a temperature of
50°C above room temperature. For proper installation of
the cooker, the following precautions must be taken:
a) The appliance can be placed in a kitchen, dining room
or bedsit, but not in a bathroom.
b) All furniture around the appliance must be placed at
least 200 mm from the top of the cooker, should the
surface of the appliance be higher than the worktop of
this furniture. Curtains should not be placed behind
the cooker or less than 200 mm away from the sides
of the appliance.
c) Any hoods must be installed according to the require-
ments in the installation manual for the hoods them-
selves.
d) If the cooker is installed beneath a wall cabinet, the
latter must be situated at a minimum of 420 mm above
the hob. The minimum distance between the worktop
and kitchen units made of combustible material is 700
mm.
e) The wall in direct contact with the back panel of the
cooker must be made of non-flammable materials.
Min.
Levelling
In order to have a perfect levelling of the cooker adjustable
feets are supplyed (see Fig.1). They can be screwed in
the seats positioned in the corners of the cooker base.
Installation
HOOD
600
mm.
Electrical connection
The power supply cable since its size depends on the
electric connection (see the following connection diagram).
400 3N
H05RR-F 5x2.5 CEI-UNEL 35363
400V 2N
H05RR-F 4x2.5 CEI-UNEL 35363
230V 1N
H07RN-F 3x4 CEI-UNEL 35364
Feeding cable installation
Terminal block opening:
Unscrew screw "V"
Pull and open the junction block lid
For the installation of the feeding cable carry out the
following operations:
position the small connection A-B according to the type
of connection that has to be performed using the
scheme shown in the figure 3.
Note: the small connections are prepared by the Factory
for the 230V monophase connection (contacts 1-2-3 are
connected to one another). The bridge 4-5 is situated in
the lower part of the terminal block.
introduce the cables (N and
re and tighten the relative screws.
fix the remaining cables on the 1-2-3 clips.
fix the feeding cable in the special cable stop and close
the cover fastening it with the screw "V".
V
Connecting the supply cable to the mains
Fit a plug, normalised for the load indicated on the data
plate, on the cable; when making the connection directly
to the mains, an omnipoIar switch with a minimum opening
of 3 mm between the contacts, must be installed between
the appliance and the mains. This switch must be sufficient
for the load and must comply to regulations in force (the
earthing wire must not be interrupted by the switch). The
power supply cable must be positioned so that it does not
exceed 50°C more than room temperature at any point of
its length. Before making the connection check that:
the limiter valve and the home system can support the
appliance load (see data plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations;
the socket or omnipoar circuit-breaker is easily
accessible once the cooker has been installed.
4
1
2
3
4
5
T
S
N
R
1
2
3
4
5
R
S N
3
4
5
1
2
N
R
) as shown in the figu-
3
2
1
B
A
N