2.3.2. Making Emergency broadcast from contacts 
-
Emergency broadcasts are activated by closing Trigger Inputs in the rear part of the unit. 
-
Contact inputs can be assigned to ALERT or EVAC messages according to configuration. It is 
also possible to set their activation mode as Level or Pulse.  
-
Once Emergency mode is activated from Trigger Inputs, EMERGENCY button lights red and 
Emergency buzzer activates. You can stop the buzzer by pressing ACK button. 
-
In order to reset Emergency mode, press EMERGENCY button again, open the trigger input 
in case of Level or activate Emergency Reset input in case of pulse. 
 
2.3.3. Manual BGM activation 
-
Select  the  zones  where  the  BGM  has  to  be  broadcasted  by  pressing  their  corresponding 
button. 
-
In LINE CONTROL press up or down arrows and then OK to select audio input.  
-
BGM  is  controlled  by  individual  zone  volume  control,  by  Master  volume,  and  also  by  the 
volume control of each input at the rear panel.  
 
Note: In dis operation mode NOVA‐500 BGM inputs are not broadcasted to NOVA‐500S zones. 
2.3.4. Automatic BGM activation 
NOVA‐500 and NOVA‐500S INPUT 1‐6 have Vox control trigger. They can be configured, using the 
software,  to  be  assigned  to  zone  outputs  when  audio  is  detected.  In  case  of  NOVA‐500  inputs, 
audio  can  be  broadcasted  to  all  system  outputs  zones,  while  in  case  of  NOVA‐500S  only  to  their 
own zones.  
 
2.3.5. Speaker line surveillance calibration by hardware 
-
Setup in the software which of the speaker lines have to be under surveillance. 
-
Set NOVA‐500 rear panel switch 8 to ON. 
-
Adjust line impedance. You can do it from the software or from NOVA‐500 rear panel switch 
7. In that case set the switch to OFF until you heard the buzzer or see panel LEDs flashing, 
then set switch 7 to ON again.  
-
Error range (5‐30%) and detection mode can only be set from the software. 
-
Detection mode could be normal or timing selectable. In normal mode lines are not checked 
if music is activated, in timing modes (between 60 seconds and  24 hours) music is cut 0.5 
seconds at each interval to measure the line. 