4.4. AUDIO INPUTS CONNECTION 
Input  the  audio  sources  to  the  INPUT  1‐6  on  rear  panel.  1‐2  inputs  are  balanced  XLR  connectors 
while  3‐6  inputs  are  2  x  RCA  unbalanced  connectors.  All  inputs  are  AUX  level  (0  dB)  and  have 
independent volume control with +6 dB/‐12 dB regulation. RCA connectors are linked internally to 
sum left and right stereo signals. 
 
Unit  includes  REC  OUT.  This  output  broadcasts  at  Line  level  the  current  output  of  the  system, 
INPUTS 1‐6, Emergency or NOVA‐12RM audio. 
 
 
 
4.5. TRIGGER INPUTS CONNECTION 
NOVA‐500  and  NOVA‐500S  include  8  contact  inputs.  These  contacts  can  be  used  to  a  activate 
Emergency messages, General messages (BGM) or assign any audio input to outputs.  
 
There  are  two  operating  modes  "Contact  mode"  and  "Level  mode".  Selection  between  modes  is 
carried out through switch nº 3 of NOVA‐500 rear panel configuration switch. ON "Contact mode" 
OFF  "Level  mode".    In  "Contact  mode"  it  is  only  required  to  close  the  contact  to  activate  the 
assigned function. In "Level mode" 2 resistors have to be installed next to activation device, these 
resistors permit the surveillance of the cable, so that if it is cut or short‐circuited failure is detected.  