In Audio PRI and line work mode, you can set up the priority of every input (00 max) as well as the 
working mode for INPUT 1‐6. Working mode can be Manual or Signal Trigger, in case of Manual 
audio  will  be  broadcasted  by  the  zones  selected  manually  from  NOVA‐500  or  NOVA‐500S  front 
panel, while in case of Signal trigger, the audio will be broadcasted by zones configured in output 
partition configuration and activated by VOX control. 
 
Note  that  inputs  of  NOVA‐500  can  be  broadcasted  by  its  own  zones  and  the  ones  of  NOVA‐500S 
units, while the inputs of NOVA‐500S units can only be broadcasted by their own outputs. 
5.3.3. Equipment ‐ EX‐HOST 
This menu is used to setup NOVA‐500S main parameters. In  EX‐Host quantity you have to define 
the number of NOVA‐500S in the system. All other parameters are the same as NOVA‐500. 
 
 