Basic control panel
I.
Switch on the machine
II. Select type of gas
III. Set thickness of material
IV. Trim the arc length, if required
A
B
4
2
3/C
1
1
Selecting type of gas
Press the key until the LED is lit at the desired
gas
Reset function
Press and hold the key for 5 seconds. Flashing
LED indicates that the relevant CO
or mix
2
gas program is reset to factory settings
2
Control knob
Turn the control knob to set thickness of
material or trim arc length
3
Selecting thickness of material
Press the key under the symbol and turn the
control knob until the desired thickness of
material is shown on the display.
4
Arc length
The arc length can be adjusted as required.
Press the key under the symbol and turn the
control knob until the desired arc length is
achieved (-9.9 to +9.9).
A
Welding voltage
B
Warning – overheating
C
Wire inching
Press the key and hold it down while
activating the torch trigger. Release the key
when wire inching starts. Wire inching stops
when the torch trigger is deactivated.
QUICKGUIDE OMEGA BASIC/AUTOMIG
Automig control panel
I.
Switch on the machine
II. Select type of material and wire diameter
III. Set one of the following parameters:
welding current, wire feed speed or thickness
of material
IV. Trim the arc length, if required
1
5
3/C
2
1
Selecting type of material
Press the key until the LED is lit at the
relevant material.
2
Selecting wire diameter
Press the key until the LED is lit at the
relevant wire diameter.
Reset function
Press and hold the key for 5 seconds. Flashing
LED indicates that the relevant program is
reset to factory settings
3
Primary parameters
Set one of the following primary parameters
at your own option and according to
relevance: welding current, wire feed speed
or thickness of material; the parameters are
closely connected in the machine.
4
Arc length
The arc length can be adjusted as required.
Press the key under the symbol and turn the
control knob until the desired arc length is
achieved (-9.9 to +9.9).
5
Control knob
Adjustment of welding current, wire feed
speed, thickness of material and arc length. If
the key for secondary parameters is active, it is
possible to trim the parameters lying behind.
A
B
6
Secondary parameters
Press the key until the desired parameter is
shown on the display.
4
Press key
3
briefly to finish.
Hotstart (t)
6
Soft start
(m/min.)
Gas pre flow (t)
Arc adjust (electronic choke)
1
UK
Set welding current (A)
Slope down (t)
Gas post
flow (t)
Burnback

Publicidad

loading

Este manual también es adecuado para:

Omega automig