Setting the 'Level changing time'
• Press the
key repeatedly to move through the possible set-
tings.
The set value will be shown by one of the 'Tank level' LEDs.
• Press the
key.
Explanation:
If the level in the tank does not change by 2% within a set time of ac-
tivating the pump cycle, the pump cycle will be stopped and an alarm
will sound. If the level does not drop, this can mean that the pump is
blocked.
The tank level LEDs show the finishing times:
100%
75%
50%
25%
2,5 min
5
Technical specifications
Power supply
Power consumption (standby)
Max. power consumption
Input:
For level sensor
Outputs:
For waste water pump
For electrically operated shut-off valve
For WC / Alarm
Dimensions
Build-in depth
18
090427.02
B
100%
75%
50%
25%
5 min
C
: 12 or 24 Volts
: 4 mA
: 100 mA
: 0 - 300 ohm (0 ohm = full, 300 = empty)
e.g. Vetus WWSENSORA or SENSORA
: max. power consumption 10 A
: max. power consumption 5 A
: max. power consumption 1 A
: 85 x 85 mm (3
: 78 mm (3