8 Faults
Fault
No Sensor
0.0 mt/m
0.0
m
V=11.6
I=0.0
Low Voltage
0.0 mt/m
0.0
m
V=7.9
I=0.0
Overcurrent
0.0 mt/m
0.0
m
V=11.6
I=300.0
9 Technical details
Power supply
Current taken
Safety class of front
Working temperature
Screen
Maximum length of chain
Resolution
Dimensions of panel
Weight
* excluding the area around the cable connections at the back of the instrument
** excluding the protective cover
Control panel / chain counter CCM
Cause
The instrument does not
receive any signal from
the sensor for more than 5
seconds even though the
'UP' or 'DOWN' key is
pressed.
The voltage supplied to
the instrument is less than
10 Volts.
The current measured by
the
current
exceeds the preset alarm
value.
: 10 to 30 V direct current
: min. 5 mA, max. 40 mA
: IP65*
: 0˚C / +70˚C (32˚F / 158˚F)
: 128 x 64 pixels
: 999 m / 999 ft
: 0.1
: 100 x 100 x 32 mm**
: 160 g
Solution
Check the connections to
the sensor.
Check whether the sensor
is faulty.
Check the electrical cir-
cuit.
Check the working of the
anchor windlass.
Check the battery.
Check the electrical cir-
cuit.
Check the electrical cir-
sensor
cuit.
Reset the alarm by press-
ing one of the keys.