Test of the safety edges
This menu allows setting the method of control of the safety edges
working.
no
Test disabled
Foto
Test enabled for optical safety edges
rESi
Test enabled for conductive rubber safety edges
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
Encoder sensitivity
This menu allows to adjust the encoder sensitivity for the obstacle
detection (leaf blocked)
0
minimum sensitivity
7
maximum sensitivity
Enabling the ADI device
This menu makes it possible to enable operation of the device
connected to the ADI connector.
no
interface disabled, any signals will be ignored
Si
interface enabled
*
PLEASE NOTE: selecting Si and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each
device. Please refer to the manual for the device.
If the Si option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the i.ADi option
End of Programming
This menu allows to finish the programming (both default
and personalized) saving the modified data into memory.
no
Further corrections to carry out: do not quit the
programming.
Si
changes complete: when programming is
complete and the data is saved, the display
shows the control panel
THE INSERTED DATA HAVE BEEN MEMORIZED: THE
CONTROL UNIT IS READY TO BE USED.