10. Remedying malfunctions

General
Malfunctions mostly occur when
the unit has not been correctly
handled, treated, or mainte-
nanced. The following table
contains possible malfunctions
and their remedy. If the mal-
Table of malfunctions
Malfunction
Motor does not start.
Shredder does not draw
through the material.
Material insufficiently cut
through.
Motor deactivates.
Abnormal noises,
unit knocks.
We explicitly state that, accord-
ing to the Product Liability Act,
we do not have to accept liability
for any damage caused by our
equipment if such damage was
18
soft brush or a cloth. (Always
wear protective gloves.)
Treatment (winterisation)
Always store the shredder in a
closed, dry room. In addition
to the above treatment, remove
function persists, please contact
the next BRILL service station.
Repair work requiring
A
specialist knowledge
may only be performed by an
authorised expert (see the list
of BRILL service stations).
Possible cause
Rotary direction switch set
to zero.
Collector box missing or not
fully in position.
Rotary direction of the blade
assembly wrong.
Collector box too full
(blade unit congested).
Aluminium counter plate
incorrectly set in the blade
assembly.
Overload protection activated
owing to constant overloading
or blocking of the blade as-
sembly.
Screws on the motor, its seat,
or the frame is loose.
caused by inadequate repairs or,
during the replacement of parts,
our original BRILL parts or parts
approved by us were not used
and the repairs were not carried
the funnel (see point 4 of
Assembly – Fig. 5, item 1) and
apply a biologically degradable,
oil emulsive treatment spray to
the exposed blade assembly.
(For instance WD 40 oil.)
Damaged mains connec-
A
tion cables may only be
exchanged by a BRILL service
station.
For safety reasons original
A
BRILL spare parts or parts
approved of by the manufacturer
only may be used.
Remedy
Set the rotary direction switch to
the correct position (see Fig. 6,
item 1).
Push collector box fully into
position.
Set the rotary direction switch
to the correct position (Fig. 6,
item 1).
Empty collector box.
Re-adjust the aluminium counter
plate (see point 8, Maintenance
of the blade assembly).
After a cooling time of approx.
5 minutes, the motor can be
re-activated.
Re-tighten screws.
out by the BRILL technical service
department or the authorised
expert. The same also applies to
extras and accessories.