Connector S140; Shielding And Cable Routing - Balluff Micropulse BTL7-A/E501-M Serie Manual Del Usuario

Ocultar thumbs Ver también para Micropulse BTL7-A/E501-M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL7-A/E501-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S140/KA_ _/FA_ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
4.4.3

Connector S140

S140
Pin
A
B
C
10 to 0 V
D
E
F
G
H
J
0 to 10 V
K
Tab. 4-4:
Connection assignment BTL7...-S140
1)
Unassigned leads can be connected to the GND on the controller side but
not to the shield.
2)
Factory setting, can be freely configured with the PC software.
Reference potential for supply voltage and EMC-GND.
3)
4.5

Shielding and cable routing

Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect transducer and controller using a shielded
cable.
Shield: Braided copper shield with minimum 85%
coverage.
Connector version: Shield is internally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing. Ground the
cable shielding on the controller side (connect with the
protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer cylinder and strong, external
magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
12
english
BTL7-... interface
-A501
0 V
Not used
1)
(output 2)
2)
10 to 30 V
Not used
1)
GND
3)
La (communication line)
Lb (communication line)
(output 1)
2)
Not used
1)
-E501
4 to 20 mA
(output 1)
2)
20 to 4 mA
(output 2)
2)
Not used
1)
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Cable length
BTL7-A
BTL7-E
Tab. 4-5:
Cable lengths BTL7
Prerequisite: Construction, shielding and routing preclude the effect of any
1)
external noise fields.
G
E
K
H
J
A
F
D
C
B
Fig. 4-11: Pin assignment of S140 (view of
connector pins of transducer),
10-pin circular plug
Max. 30 m
1)
Max. 100 m
1)

Publicidad

Tabla de contenido
loading

Tabla de contenido