8

Teach-in with the calibration device

NOTICE!
Interference in function
Teach-in while the system is running may result in
malfunctions.
► Stop the system before performing teach-in.
Initial situation:
Transducer with magnet within measuring range
Activate teach-in
Œ
► Press
for at least 4 s.
Set null point
► Bring magnet to the new null point.
Œ
► Press
for at least 2 s.
⇒ The new null point is set once the button is
released.
Set end point
► Bring magnet to the new end point.
► Press
for at least 2 s.
⇒ The new end point is set once the button is
released.
Invert curves
Œ
► Simultaneously press
and
both LEDs are illuminated in red.
⇒ The curves of both outputs are inverted once the
buttons are released.
End teach-in
► Briefly press
Œ
and
simultaneously (< 1 s).
⇒ The current position value is displayed once the
buttons are released.
Any of the individual steps for settings can be
selected. The teach-in process can be ended at
any time.
www.balluff.com
> 4 s
> 2 s
> 2 s
for at least 4 s, until
> 4 s
< 1 s
LED legend:
LED not on
LED green
LED red
LED display Displayed values (example)
LED1 LED2 At 0 to 10 V At 4 to 20 mA
1
1
2
1
2
1
2
LED 1 and LED 2 flashing green-green in
alternation
5.39 V
9.15 mA
5.39 V
9.15 mA
1.04 V
4.82 mA
0.00 V
4.00 mA
9.89 V
19.13 mA
10.00 V
20.00 mA