Possibilities
Standard functioning (without Ecos modules):
In the basic version during stand-by a point (.) will be
shown on the display. As soon as the main time is
connected the display will change into two hyphens
(--). The maximum period of time to be programmed
®
in the PayMatic
is 15 minutes. The main time starts
after inserting a coin or by means of a continuous
external
drive.
The
programmable. It may be chosen between the
standard "continue" output, which means that both
relays are activated during main time, and a "pulse"
output, which means that a pulse is generated at the
beginning and the end of the main time. The
operator may choose either to allow the creation of a
pause during the main time or not. If a pause is
allowed, it can be created by pressing the up key.
The operator can also choose between interrupting
and continuing the main time during the pause
mode.
Extra functioning (with all Ecos modules):
®
The PayMatic
can be activated with three freely
programmable time-segments. The duration of these
time-segments can be set at 0 to 255 minutes. The
®
PayMatic
starts with a prior time. During the prior
time the length of the main time will be shown
intermittently on the display. During the prior time it
is possible to reduce the main time if necessary. The
prior time can also be bypassed so that the main
time will start automatically. During the main time the
remaining time will be shown on the display. Another
possibility consists of the automatic main time
adjustment based on the progression of the service
counter. The main time is automatically followed by
the post time. During the post time "Cl" (cool) is
displayed. After the post time it is possible to activate
a clean function, in this case "CL" is displayed
intermittently. This clean function inhibits the
®
PayMatic
. Furthermore, there is an "after start"
function by means of which an extra main time of 30
seconds can be given at the end of the whole
session.
Registration facilities, as for example coin-, running
time- and servicecounters can also be used. The
start and running time counters may either be
activated as counters, which can be reset, or as
cumulative counter, which can not be reset.
Automatic representation of the Running time
counter is affected by pressing the Down key during
3 seconds. The service counter generates a SR
(service message) on the display.
®
PayMatic
output
®
PayMatic
AD2400(-B) Version 2.0 5-11-2007
-
www.inepro.com
is
Main time
0-15minutes
Prior time
0-255minutes
Main time
0-255minutes
Post time
0-255minutes
-
Start by means of;
- Insertion of coin
- External drive
Display indication
- during stand-by
one point (.)
- during operation
two hyphens (--)
Pause facility
2 possibilities of
programming the
output
Quick start function
Main time reduction
Real time indication
Minimum and
maximum coin control
Automatic main time
adjustment
Clean function
After start function
Service counters
Complete registration
facilities
Simple reading of the
running time counter
13