Appendix
Connection sheet for a 4 pole 20 A contactor
When using the timer with bigger machines, such as industrial washing machines / dryers, we
recommend a 4 pole contactor in order to withstand higher power.
Connection sheet for solenoid valve
The RFI-cap always has to be connected to the power supply of the Pico-Timer.
"Phase" in
13 & 14
auxiliary contacts
1
3 5
13
A1
4-polige
magneetschakelaar
A2
2
4 6
14
Switched "phase"
output
230V AC supply
RFI-CAP
Transparent
.
230V AC
Solenoid valve
Supply
EREA security
transformer
24 AC / 63VA Output
V.D.R.
RFI-CAP
Transparent
Warning
At 230 Volt:
Connect the 2 black wires to supply terminals
-
Connect the transparent wires to earth
-
At 24 V AC/DC
Connect the 2 black wires to terminals + and –
-
The transparent wire will not be used.
-
®
PayMatic
AD2400(-B) Version 2.0 5-11-2007
-
www.inepro.com
Pico-Timer
Date:
Tested :
N
O
230V AC
!
24V AC/ DC
pow er connection
Pico-Timer
Date:
Tested :
N
O
230V AC
!
230V AC
24V AC/DC Power
connection
-
19