Settings
Function F5, Minimum amount of coins
Minimum amount of coins which have to accepted in order to activate the PayMatic
coins for 5 minutes. The value of this setting has to be at least 1. If the programmed value is higher
than 1, the coins will be shown on the displayed until the necessary amount is reached.
Example (Function F1 is set at 5 minutes)
1
e
1
coin
5 minutes
e
2
coin
-
e
3
coin
-
Total time
5 minutes
Value F4
1
Value F5
1
Function F6, Service indicator 1
The maximum amount of programmable running hours before a revision service is required. This
register will count down per 1000 minutes of relay 1 activity. The value of this register represents the
number x 1000 minutes, e.g. 5 = 5000 minutes. When the counter reaches zero, the "SR" message will
appear on the display. This is the standard message to indicate that a revision "service" is required.
The maximum value to be programmed is 254 (x 1000 minutes). If the value is set at 255, the service
counter is out of action.
Note: The timer will keep running as usual.
Function F7, Service indicator 2
This service counter works as described in function F6 but as soon as this counter has counted down
to zero (service counter = 0), the PayMatic
Function F8, Buzzer setting
This setting is not effective for this machine.
Function F9, Clean Function
By means of this function it is possible to force the cleaning of a connected device. After the posted
®
time the PayMatic
does not accept any further coin anymore. This blockage can be raised by pressing
the internal or external up key for 3 seconds. To indicate the necessity of cleaning CL will appear
intermittently on the PayMatic
Setting "00": Clean function off
Setting "01": Clean function on.
Function FA, Standard or external start mode
Setting "00": The PayMatic can be started by pushing the Timer button or by generating a puls, which
is longer as 200 msec, on the external connection (remote button print).
Setting "01": The PayMatic can be started by generating a pulse between the 20 and 200 msec. This
setting is dedicated for mechanical coin mechanisms.
Note: in case the coin mechanism input is selected (setting "01") then starting the timer with the Timer
button is not possible. When the timer button is selected (setting "00"), then by generating a signal on
the coin mechanism input, the pre-time can be bridged to start the main-time. (This can be done by
short circuiting the coin mechanism connection pins)
This setting must be set on 01 for this machine.
(ECOS module EM-05)
2
5 minutes
0 minutes
5 minutes
5 minutes
-
-
10 minutes
5 minutes
2
1
1
2
(ECOS module EM-06)
(ECOS module EM-06)
®
is inhibited.
(ECOS module EM-08)
(ECOS module EM-09)
®
display.
®
PayMatic
AD2400(-B) Version 2.0 5-11-2007
-
www.inepro.com
3
4
0 minutes
10 minutes
-
10 minutes
2
2
-
®
. For example, 3
5
6
5 minutes
0 minutes
5 minutes
10 minutes
5 minutes
5 minutes
15 minutes
15 minutes
3
3
1
2
15