CONNECTING THE BATTERY TESTER
1- Make sure that the area is well ventilated before performing a test.
2- Tester for 12 V batteries.
3- Before running a test on the battery, ensure that the ignition and the consumers are switched off. Close all doors and
the boot.
4- Make sure that the battery connections are clean. If necessary, clean them with a wire brush.
Any presence of oxidation between the tester terminals and the battery connectors or between the battery connectors
and the battery terminals reduces the effectiveness of the tester.
5- Connect the negative (black) terminal to the negative terminal of the battery. Connect the positive terminal (red) to
the positive terminal of the battery.

BATTERY TEST

1. The screen lights up and displays the battery voltage. Press the «ENTER» key to continue.
2. Select the battery type (Standard liquid battery or Sealed battery: VRLA/GEL/AGM) with the arrow buttons and click
on «ENTER»‚ to confirm.
3. Select the standard (marked on the battery) with the arrow buttons and click on «ENTER»‚ to confirm. (Standard :
CA, MCA, DIN, IEC, EN, SAE)
4. Enter the starting current indicated on the battery («A») and confirm.
5. If the display shows «CHA», specify whether or not the battery is charged with the arrows and confirm with «EN-
TER».
6. One of the results below is displayed.
Battery test result
Résultat
BATTERIE OK
OK FOR RECHARGE
CHARGE & TEST
TO BE REPLACED
ERROR

SYSTEM TEST

1. The display shows the battery voltage XX.XX on screen. Press the «ENTER» button.
2. Press the arrow buttons ▲\▼ to select the «SYST» system test and press the «ENTER» button.
3. Power off all vehicle consumables, such as lights, air conditioning, radio, etc. before turning on the engine.
5. The screen displays «CrAn», press the «ENTER» button to read the minimum battery voltage.
6. Start the engine. The result is displayed
Result of the start voltage test
Result
Green LED
Yellow LED
Red LED
6
NBT 200
Screen display
Green light
XXXX (CCA value)
Green and yellow light
XXXX (CCA Value)
Yellow and red light
XXXX (CCA value)
Red light
XXXX (CCA value)
ERR
in red on the screen
No problem detected. Unit operating normally.
Problem with the starting system. Check connections, cables and the starter.
Check that the connections are good. If everything is properly connected, re-
place the starter.
Analysis
The battery is operational.
Battery in good condition but low state of charge.
Charge the battery and perform the test again. If
the result remains the same, change the battery.
The battery is nearing the end of its life.
Replacement required.
The battery is higher than 1200 CCA (SAE) or a
problem at the cell level is found (short circuit...).
Replace the battery.