PBT 600 – Battery Conductance Testeur
This function is to set standby power, which is OFF by default.
For some luxury vehicle, ECU must be power on. Once power off, ECU will
automatically locked.
Standby power function offers ECU power for short time when the vehicle battery
needs to be replaced to avoid automatic lock.
When standby power function is ON, tester will use internal 9V battery to supply
power after its clamps are connected in principle of "Red to Anode & Black to Cathode"
with the battery connection cable.
CAUTION: when standby power function is ON, do not touch Red & Black
clamps with each other to avoid short circuit.
After using, press Return key, tester will automatically turn off the standby power.
NOTE: 9V battery, due to its small capacity, can only supply power for short
time.Before using the tester as standby power, make sure the internal 9V battery is
with sufficient capacity, and try to complete the battery replacement in a short time
to avoid the automatic lock caused by power off.
13.14 Test Number
Input test number before testing to manage and claim battery. Close it if do not need.
13.15 Display Set
To decide whether display internal resistance or CCA value on the result screen.
Daily Maintenance
1. Screen Not Light
Check whether the Power is turned on.
Check connection with the battery whether it's well connected.
Battery voltage is too low to drive the tester (< 1.0V). Fully charge the battery and
retest.
Internal 9V battery may need to be replaced. Replace the 9V battery and retest.
2. Printer Common Fault
Printer paper jam: paper not properly placed. Open the paper box and reload the
paper.
Paper Not Move: paper used up. Replace new print paper.
UK - 16