14193_english_spanish guts 1/29/02 10:40 AM Page 10
HEATWAVE XL CONTROL PANELS
1) POWER LIGHT - Indicates power is connected to the unit.
2) FLOW LIGHT - Indicates pressure (Flow) is present in the water plumbing.
3) DEFROST LIGHT - Indicates unit is in the defrost cycle (Icebreaker/models) or air temperature is too low (Standard Units).
4) LOW REFRIGERANT PRESSURE - Indicates low refrigerant pressure in the refrigeration system.
5) HIGH REFRIGERANT PRESSURE - Indicates high refrigerant pressure in the system. Heater may not have adequate water flow.
6) POOL/OFF/SPA SELECTOR SWITCH - Selects between pool and spa thermostat and the off position.
7) ON/OFF SWITCH - (
) Indicates ON (O) Indicates OFF.
8) POOL TEMPERATURE CONTROL - Controls pool temperature set-point.
9) SPA TEMPERATURE CONTROL - Controls spa temperature set-point.
10) HEAT/COOL SELECTOR SWITCH - Toggles between the HEATING and the COOLING mode.
11) POOL FLOW LIGHT - Indicates pressure (POOL WATER FLOW) is present in the unit.
12) SPA FLOW LIGHT - Indicates pressure (SPA WATER FLOW) is present in the unit.
13) TIME CLOCK EXTEND ON/OFF SELECTOR SWITCH - When switched to the EXT. position extends the pool pump hours of operation to support the
heater (If interfaced).
STANDARD
"ICE BREAKER"
OPTION
ATV
OPTION
DX
OPTION
Page 10
A070296A