Check to be sure the
power light is on. If
the power light is off,
check for a tripped
circuit breaker. Reset
the circuit breaker if
necessary.
Problem solved.
Unit Fails to Operate
Yes
toggle switch in the on
Yes
Yes
Is the thermostat
turned up and the
position?
Is the unit
operating
correctly?
Is the unit
operating
correctly?
Page 18
No
Place the toggle
switch in the on
position and rotate
both thermostats to
the maximum setting.
No
Check to see if the
pool pump is
operating and the flow
light is on. Make sure
all isolation valves are
in the correct position
and the filter and
pump basket are
clean.
No
The heater is
equipped with a five
minute delay.
Wait at least five
minutes to allow the
timer to reset.
Call Aqua Cal for
technical assistance
at 800-786-7751.