Aquacal 5213 Manual De Instalación Y Operación página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

14193_english_spanish guts 1/29/02 10:39 AM Page 6
Pool & Seperate Spa - DX Installation
Heat Pump w/Solar Panels
LEGEND
3 - 3 way valve
C - Chlorinator (if used)
D - Drain
F - Filter
H - Heat pump
P - Pump
R - Return
S - Skimmer
* Note: Bypass check valve spring rate is specific to each
model. Reference external bypass check valve selection chart
for specific rate.
Page 6
NOTE:
Spa pump must be a minimum 1/2 hp larger than the
pool pump size.
Typical Pool/Spa Spill over - ATV Installation
Heat Pump w/Gas Heater backup
- Flow Switch (ADT Kit)
- Throttle valve
- Thermometer
- Hartford Loop
- *
- Flow meter
000352D