Adjusting the automatic safety release function

UN41-0147MF
The automatic release is designed to protect the trans-
mission components from overloads (e.g. if the dispens-
er jams).
The device is already set by the manufacturer during the
testing stage, but can be adjusted by the user according
to requirements.
English language
ADJUSTMENT INFORMATION
For adjustments, proceed as outlined below.
1) Turn the ring nut (A) clockwise to increase the release
resistance (i.e. less sensitive).
Turn the ring nut (A) anticlockwise to decrease the
release resistance (i.e. more sensitive).