Mosa GE 4000 LDS/GS Manual De Uso Y Mantenimiento página 35

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REV.1-06/11
Technical data
GENERATOR
*Stand-by single-phase power
*PRP single-phase power
Frequency
Cos ϕ
* Output powers according to ISO 8528-1
ALTERNATOR
Type
Insulating class
ENGINE
Mark / Model
Type / Cooling system
Cylinders / Displacement
*Stand-by net power
*PRP net power
Speed
Fuel consumption (75% of PRP)
Engine oil capacity
Starter
* Powers according to ISO 3046/1
GENERAL SPECIFICATIONS
Battery charger d.c.
Tank capacity
Running time (75% of PRP)
Protection
*Dimensions / max. Lxwxh (mm)
*Weight (dry)
**Acoustic power LwA (pressure LpA)
* Dimensions and weight without trolley/trailer. **For indoor use
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
(L
Acoustic Noise Level
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
)
of 95 dB(A)
WA
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE: the symbol
according to 2000/14/CE directive.
Technical data
GE 4000 LDS/GS
3.6 kW / 230 V / 15.6 A
3.3 kW / 230 V / 14.3 A
50 Hz
1
self-excited, self-regulated, brushless
synchronous, single-phase
H
Lombardini / 15 LD 350
Diesel 4-Stroke / air
1 / 349 cm
4.6 kW (6.3 HP)
4.3 kW (5.8 HP)
3000 rpm
1 l/h
1.2 l
manual recoil
12V - 10A
4.3 l
4.3 h
IP 23
785 x 410 x 515
64 Kg
99 dB(A) (74 dB(A) @ 7 m)
ACOUSTIC POWER LEVEL
)
- Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
WA
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
3
OUTPUT
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
GE 4000 LDS/GS
M
1.5

Publicidad

Tabla de contenido
loading