11.Plug the machine in and switch it on with no coffee.
12. While pressing the indexing pointer with one hand, with the other screw up the
adjustment nut (5) until the 2 grindstones make slight contact (slight noise).
13.Stop the machine.
14.Unscrew the graduated plate (12) retaining screws and re-index the graduated plate "0"
(12) with the indexing pointer (7) (fig. L).
15.Loosen the adjustment nut (5) by 5 to 10 notches
16.With coffee in, adjust the ground coffee setting (see "Grinding adjustment" section).
FAULT FINDING
If for an unknown or involuntary reason your No. 60 grinder stops or no longer provides its
function, please proceed as follows:
• Try to determine the exact reason for the machine stopping.
• Depending on what you identify, refer to the section below which is most relevant to your
problem.
• If, when you are working on the machine to resolve the problem, you need to remove the
container (2), remember to close the bean container shutter (6).
• In all circumstances, if the problem persists, turn the electric power supply off, unplug the
mains supply lead plug (10) and call on someone from the maintenance department or
contact an approved SANTOS dealer.
The machine will not start:
• Check: the mains power supply and the condition of the power supply lead (10).
• Check that the On / Off switch indicator (11) lights up when the switch is in the 1
position. If not, replace the switch.
• Check that the dose measurer (31) and the dose measurer lid (24) with the detection
paddle (14) and its magnet (19) are correctly positioned on the coffee grinder.
• Check that the grindstones (9) are not making contact preventing the motor from starting;
unscrew the nut (5).
• Check that there are no foreign bodies stuck between the grindstones (9).
• Inside the machine, check the condition of the electric wires and the connections (on the
switch (11) and on the component support module (25) (fig. M and fig. T)) (the electric
components can be accessed without dismantling the machine); also check on the dose
measurer presence sensor (27) and the dose measurer filling level sensor (28) located
behind the dose measurer support plate (26) (fig. O).
• Check the electric components, replacing them one by one.
The machine stops automatically after a too long operating time:
The No. 60 coffee grinder stops automatically if the pre-programmed maximum continuous
operation time is reached. This protection provides the means for preventing any overheating
of the motor. Where the coffee grinder has been stopped in this way, the following is required
to remedy it:
• Check that there are still coffee beans in the bean container (2).
• Check that the bean container shutter (6) is in the open position.
98160 06/2006
21
www.santos.fr