Technical Data - Festo VMPA-ASI-EPL-8E8A-Z Serie Manual Del Usuario

Terminal de válvula mpa con interfaz as
Ocultar thumbs Ver también para VMPA-ASI-EPL-8E8A-Z Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4

Technical data

VMPA-ASI-EPL-...-8E8A-Z/-CE
General technical data
Protection class according to EN 60529
Electromagnetic compatibility
Protection against electric shock
(protection against direct and indirect
contact as per IEC/DIN EN 60204-1)
AS-Interface data
(Standard/extended address mode)
– IO code
– Ident. code
– Ident. code 1
– Ident. code 2
– Profile
AS-Interface bus connection
– Voltage range (protected against
incorrect polarity)
– Residual ripple
– max. current consumption
– Electronics (input circuitry
for 0-status incl. LED)
– Max. resultant current for inputs
– Max. resultant current for outputs
(Valves incl. LED)
28
See Pneumatics manual
P.BE-MPA-...
IP65 (fully mounted)
Tested to EN 50295,
low voltage switchgear
By means of PELV power
supply unit (Protected
Extra-Low Voltage)
VMPA...-Z
IO = 7
ID = F
ID1 = F
ID2 = E
S-7.F.E
DC 26.5 ... 31.6 V
≤ 20 mVss
< 25 mA
350 mA
MPA1: 540 mA
MPA2: 1,065 mA
Festo VMPA-ASI-EPL-...-8E8A-Z/-CE 1104b English
VMPA...-CE
IO = 7
H
H
ID = A
H
H
ID1 = F
H
ID2 = E
H
S-7.A.E
H
H