CPV...-DN8
5

Technical data

Type
Protection class as per EN 60 529 (DIN
40050)
Temperature range:
– during operation
– during storage/transport
Pin 2 – Load voltage connection valves
– Nominal value
– Tolerance
– Power consumption
Pin 2, 3 – Bus interface / internal elec-
tronics
– Not protected against incorrect polarity
– Nominal value
– Tolerance
– Power consumption (at 24 V)
Protection against electric shock (protec-
tion against direct and indirect contact
as per EN 60204-1/IEC 204)
– Interference transmission
tested as per EN 55011
– Noise immunity
tested as per EN 50082-2
*) The CPV calve terminal with DeviceNet direct connection can with individual
approval, also be used in the residential sector (residential, business and
commercial premises, small companies).
18
CPV...-DN
IP 65 (plug connector inserted or fitted
with protective cap)
- 5 °C ... + 50 °C
-20 °C ... + 70 °C
DC 24 V
21.0 V ... 26.4 V
Sum of all switched on CPV
solenoid valves; power consumption
DC 24 V
11.0 V ... 25.0 V
50 mA
by connection to a PELV power unit
(Protected Extra-Low Voltage)
*)
Limit value class A
9905NH