ABIPLAS
CUT 200 W/MT
6.1 Equipping the ABIPLAS
1
2
1
Bevel nozzle
2
Spatter protector
3
Protection cap
4
Plasma nozzle
Fig. 2
Equipping the torch body with standard wear parts
®
CUT 200 W/MT manual cutting torch
3
4
5
Swirl ring
6
Electrode
7
Insulator
NOTICE
• Fastening on the protection cap too tightly can damage the insulator and
the swirl ring. Fastening it too loosely lowers the service life of the wear
parts.
• Please ensure that the swirl ring is correctly positioned. The air holes
should always point towards the electrode tip.
• The plasma-cutting torches are equipped with a safety cut-off device for
the operator's protection. This automatically interrupts the input current
circuit if the protection cap is removed. Two spring-mounted contact pins
are actuated when the protection cap is screwed on. If the spring effect
of the contact pins is impeded, the safety cut-off device can become
ineffective.
• Ensure that all contact surfaces between the spring-mounted contact pins
and the contact ring on the protection cap are kept clean.
• Disconnect the plasma power source when replacing wear parts.
1 Screw in the insulator hand tight only.
2 Attach the electrode.
3 Attach the swirl ring.
4 Attach the selected plasma nozzle.
6 Putting into operation
5
6
7
10
8
Torch body
9
O-Ring 22x2 (x 3)
10 O-Ring 5x1 (x 2)
8
9
EN - 13