Start Your Session; During The Stimulation Session - Compex WIRELESS Guia Del Usuario

Ocultar thumbs Ver también para WIRELESS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74

4.4 START YOUR SESSION

SWITCH ON THE MODULES BEFORE STARTING THE
STIMULATION SESSION
Before initiating the stimulation and mi-SCAN measurement,
you have to turn on the modules one after another by pressing
EN
their On/Off buttons. Once the 1st module is detected by the
remote control, you can switch on the 2nd module and so on up
to the 4th module. If you only want to use two modules for your
session, just press the START button after the second module is
detected.
Please note: For a session which is optimally adapted to your
muscles, Compex recommends that you always perform an
mi-SCAN measurement before starting a stimulation session.
DISPLAY EXPLANATIONS
Remaining time in
Bar graph of energy level
PROGRAMMES INDUCING MUSCLE CONTRACTIONS
Top sector: contraction phase
Bottom sector: active rest phase
PROGRAMMES NOT INDUCING MUSCLE CONTRACTIONS
The top and bottom sectors show the time remaining in the
specific phase
User Manual
minutes
Energy level (goes up to 999)
Number on black background:
active background
Number on grey background:
inactive channel
Remaining number of
contractions or indication of
warm-up or cool-down phase
BEGINNING OF THE STIMULATION SESSION: MI-SCAN
MEASUREMENT
This feature adapts the electrostimulation session to each
individual user's physiology. Just before starting your stimulation
session, mi-SCAN probes the chosen muscle group and
automatically adjusts the stimulator parameters to the excitability
of this area of the body. It is a truly personalized measurement. In
order to ensure that your session is as effective and comfortable as
possible, it is highly recommended that you perform the mi-SCAN
at each session.
This function is implemented at the start of the programme by
a short sequence during which measurements are taken. You
should remain completely still and be perfectly relaxed throughout
the measurement test. Once the test has been completed, the
programme can start.
Start your session without the mi-SCAN measurement
Start your session with the mi-SCAN measurement (see explanation below)
Back to previous screen

DURING THE STIMULATION SESSION

Stimulation always starts off at 000 (+++).
N.B.: Active rest phase stimulation energies are automatically
set at 50% of contraction energies. These can be modified
during the rest phase. Once modified, they will be totally
independent of the contraction energies.
13
Active channel
(Black background)
Inactive channel
(Grey background)
Pause the stimulation
Increase or decrease the stimulation energy levels
of the selected channels
Select the channels on which you wish to act.
When a channel is active, the LED of the button gives
off a solid blue light.
Please note: by default, all channels are active at the
start of a session. Please note: pressing the button for
a given channel for more than 1 second activates that
channel and deactivates all the others.

Publicidad

Tabla de contenido
loading

Tabla de contenido