4) Enter the second frequency using the Control knob.
5) The Dual watch begins automatically. If a signal is received, the receiver will remain
on the active frequency for the duration of the 'Busy Timer' setting in the Menu
setup. If the 'Busy Timer' is set to Busy the receiver will stay on the active frequency.
6) To stay on an active frequency indefinitely or to stop the Dual Watch function press
Func DW again. The receiver will exit the Dual Watch function.
MEMORY BANKS
The scanner memory storage area has a capacity of 00 locations. These are split and
stored into 10 banks. Each bank has 0 channel storage capability.
n How to Memorize Frequencies
The Memory area allows the user to manually store up to 00 individual frequencies.
The default memory banks are labelled 0 to 9.
STORING FREQUENCIES INTO THE MEMORIES
To store a frequency into one of the memories:
1) Press the E/VFO key to select VFO Mode.
) Press the BANK BAND key to select the
required Band.
3) Select the frequency that you want to store
using the control knob.
4) Press Func MW to enter the Memory Write
mode.
5) The receiver will find and display an empty
memory bank and memory location
automatically.
6) If required, use the BANK BAND key to
select a new memory bank.
7) To change the memory location, rotate the control knob.
8) Press Func MW again to store the frequency.
14
4
4
INSTRUCTION MANUAL
1
8
5
TSC-100R/100RBT
3 7
2 6