Commissioning
6.4.1

Transmitter with dual-compartment housing

„A"
1
2
3
Fig. 50
A Integral mount design
B Remote mount design
1 Housing cover
2 Transmitter plug-in module
3 Fixing screws
IMPORTANT (NOTE)
The backplane is mounted in the transmitter housing (not the transmitter plug-in module).
Configure the outputs as follows:
1. Switch off power supply.
2. Open the housing cover.
3. Remove the mounting screws for the transmitter electronics unit
4. Pull out the transmitter electronics unit
5. Set jumpers on backplane in accordance with the following table.
Jumper
BR901
BR902
BR903
6.
50 - EN
„B"
3
Number
active
passive
Read only
integral
remote
Reinstall the transmitter electronic unit in reverse order
5
4
4 Backplane (in the transmitter housing)
5 Jumper (BR901) for active / passive current output
6 Jumper (BR903) for integral / remote mount design
7 Jumper (BR902) for hardware write protection
Function
Current output 31 / 32 active
Current output 31 / 32 passive
Hardware write protection active
Transmitter with integral mount design
Transmitter with remote mount design
FEX300, FEX500
6
7
G00679-02