6. Observed Standards

ABNT NBR NM 60335-1
IEC 60335-2-64
NR-12 according to the order Nº 197, December, 2010

7. Maintenance

*
It is considered MAINTENANCE the group of actions that aim to offer and grant
the perfect working condition of the equipment, enlarging its useful life, and general user
safety.
* Cleaning – Check item 5 Cleaning of this manual.
* Cords – Check if the cords are in good condition, without any damage and if all electrical
terminals are in good condition and without oxidation.
* Contacts – Check the ON/OFF button, Reset button, electronic circuits and make sure
that all these components are working correctly and in good condition, and that the use of
the equipment is occurring in a normal way, without any inconvenient.
* Installation – Check the installation of Your Equipment as per the item
Installation and Pre Operation of this manual.
* Useful life of the equipment – 2 years for the use in a normal work shift.
Items to check and execute monthly:
• Check the electrical grid and installation of the work place;
• Measure the amperage intake of the electric power supply;
• Measure the working current and compare it to the nominal current;
• Check the electrical terminal connections of the Equipment to avoid contact
failures;
• Check for possible wearing or looseness in the electric motor shaft;
- 2 – Items to check and execute every 3 months:
• Check the ON/OFF button, Reset button, electronic circuits for signs of overheating,
damaged insulation or mechanical damage.
• Check for possible looseness in the assemblies and bearings
•Check the retainers, o'rings, v'rings and other seals