c. Three ways to wake up:
Turn off the power switch of the soldering station and then turn it on.
Press any key.
Pick up the soldering iron(handle).
d. ThreeOnly when the handle is placed on the soldering iron stand can the soldering station enter the sleep state within the
specified time.
3) Sleep setting
a. The window displays the
shall be longer than the sleep time,
b. The off time setting range is from 0 to 250 minutes.
4) Sleep temperature setting
a. The window displays the
temperature set value.
b. The sleep temperature setting range is from 50 ° C to 250 ° C.
5) Alarm Up Temp
a. The window displays the
temperature set value. Once the difference between Set Temp and Real Temp exceeds the Up Temp, the soldering station will
give an alarm in the alarm mode.
b. The alarm Up Temp setting range is from 0 ° C to 99 ° C.
6) Alarm Down Temp
a. The window displays the
temperature set value. Once the difference between Set Temp and Real Temp.exceeds the Down Temp, the soldering station will
give an alarm in the alarm mode.
b. The alarm Down Temp setting range is from 0 ° C to 99 ° C.
3.4 Temperature Calibration
1) Each time the soldering iron, the heating element or the soldering bit is replaced, the temperature of the soldering bit shall be
calibrated again.
2) This machine is designed with the digital temperature calibration mode. In this mode, you can enter the correction value by pressing
the corresponding keys., making the adjustment easy and convenient
3) Method for recalibrating the soldering iron temperature: A soldering iron thermometer is to be used for calibration, and this method
is relatively accurate.
4) Steps for temperature calibration by a soldering iron thermometer:
a. Set the soldering station at a certain temperature.
b. Measure the temperature of the soldering bit with a thermometer and record the reading when the temperature is stable.
c. Press and hold the "*" key, and press the " △ " and " ▽ " keys simultaneously to enter the Cal Temp mode.
d. The LED display does not blink. Press " △ " or " ▽ " key to enter the temperature measured by the thermometer into
the soldering station, and then press the "*" key to finish the temperature calibration of the soldering iron.
5) Repeat the above calibration steps if there is still an error in the temperature.
It is recommended to measure the temperature of the soldering bit with a 191/192 thermometer.
If it is locked by the password, the temperature cannot be calibrated until you enter the correct password.
02002A
after entering the off time setting. Press " △ " or " ▽ " key to change the off time, which
after entering the sleep state setting. Press the " △ " or " ▽ " key to change the
after entering the alarm Up Temp setting. Press the " △ " or " ▽ " key to change the
after entering the alarm Down Temp setting. Press the " △ " or " ▽ " key to change the