...black of power (black out)
If power is missing for a time less than Pr48, when restored the boiler immediately re-starts from operative state it had before power outage (recovering the
set work power).
If power is missing for a time greater than Pr48, when restored the boiler is placed at "STOP FIRE" (stand-by) mode and carries out the entire switch off
cycle until it cools down. Once this phase is completed, the boiler can be normally switched on to proceed working at the set power.
Previous state
OFF
START
START
P-LOAD PELLET
FLAME STAND-BY
FIRE PRESENT
FIRE PRESENT
WORK (any phase)
WORK (any phase)
BRAZIER CLEANING
BRAZIER CLEANING
FINAL CLEANING
FINAL CLEANING
STOP FIRE

CIRCUIT BOARD PARAMETERS

THE PARAMETERS MEMORISED ON THE CIRCUIT BOARD ARE FUNDAMENTAL FOR THE CORRECT FUNCTIONING OF THE BOILER.
THE PARAMETERS GIVEN BELOW ARE ALREADY MEMORISED IN THE BOILER INSPECTION PHASE DIRECTLY IN THE FACTORY.
THESE PARAMETERS ARE THE RESULT OF CAREFUL TESTS WITH VARIOUS TYPES OF PELLETS AND MUST NOT BE CHANGED WITHOUT
THE AUTHORISATION OF KLOVER srl, SO AS NOT TO JEOPARDISE BOILER FUNCTIONING.
ALL RESPONSIBILITIES ARE DECLINED FOR DAMAGE CAUSED BY INCORRECT INTRODUCTION OF THE PARAMETERS.
Parameter
Menu level
Pr38
M – 9 – 4 – 01
Re-ignition block
Pr39
M – 9 – 4 – 02
Flue gas intake device switch-off time
Pr40
M – 9 – 4 – 03
Pre-load time in ignition
Pr41
M – 9 – 4 – 04
Stand-by time after pre-load
Pr42
M – 9 – 4 – 05
Intake device speed in pre-load phase
ON/OFF Temperature hysteresis on "SET
Pr43
M – 9 – 4 – 06
H2O" and "SET DHW"
Delay to economy switch-off (timer after
Pr44
M – 9 – 4 – 07
reaching "SET H2O")
Pr45
M – 9 – 4 – 08
Power change delay
ON/OFF Temperature hysteresis on "SET
Pr46
M – 9 – 4 – 09
ROOM"
Pr47
M – 9 – 4 – 10
Keypad block enabling
Pr48
M – 9 – 4 – 11
Automatic re-ignition after black-out
Pr49
M – 9 – 4 – 12
Pellet level sensor enabling
Pr50
M – 9 – 4 – 13
Pump ignition for over-temperature safety
Black-out duration
State after power restore
Any
OFF
duration < Pr48
START
duration > Pr48
START
Any
BLACK OUT ALARM
Any
BLACK OUT ALARM
duration < Pr48
FIRE PRESENT
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
duration < Pr48
WORK (any phase)
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
duration < Pr48
BRAZIER CLEANING
duration > Pr48
STOP FIRE with automatic re-ignition after machine cooling
FINAL CLEANING and after cooling  OFF
duration < Pr48
FINAL CLEANING and after cooling  OFF
duration > Pr48
Any
STOP FIRE
"Various calibrations" (Menu M – 9 – 4)
Description
Display writing
Measurement
RE-IGNIT BLOCK
Minutes
MIN-INT OFF
Minutes
IGNIT- PRE-LOAD
Seconds
AFTER-PRE STAND-BY
Seconds
PRELOAD FLUE GAS-
Revs/min
INTAKE DEVICE
DELTA ON OFF AUTO
DELAY-OFF AUTO
Minutes
POWER CHANGE
Seconds
DELTA ON AUTO
KEYS BLOCK-EN
On – off
BLACK OUT RE-IGNITION
Seconds
PELLET RESERVE
On – off
PUMP SAFETY
21
Value field
0 – 10
0 – 20
0 – 225
0 – 255
350 – 2800
°C
0 – 20
2 – 120
0 – 60
°C
0 – 15
On – off
0 – 60
On – off
°C
60 - 90
Database
6
10
90
170
2100
5
30
20
2
Off
30
On
83