You will know the cavity is com-
pletely full when water comes out
of the control drain (Fig. 1 B1).
When filling is complete, simultaneously
close the filling gate valve and the water
control drain in the cavity (Fig. 1-2 B).
Having successfully filled the cavity
with water, proceed filling the pot.
FILLING THE POT / see SECT. IMA-
GES - REF. l)
Make sure that the cooking compart-
ment drainage gate valve is at the
"Closed" position (Fig. 3).
The drainage gate valve opens
by lifting the handle and turning
it 90°/180° (Fig.3A -3B) respect
to the closed position (Fig.3).
Lift the lid of the pot and fill the co-
oking compartment with the material
to be processed.
When filling the cooking com-
partment, respect the level indi-
cated on the inside (see IMG
REF. l)
Do not introduce large pieces of
kitchen salt into the cooking com-
partment as it deposits at the bot-
tom and does not completely dissolve.
Do not put salt in cold water.
SEE SECT. IMAGES - REF. m)
Hot or cold water can be introdu-
ced into the cooking compartment
by acting on the 2 knobs (Fig.4).
In order to fill the cooking compart-
ment with water, you must:
Lift the lid of the cooking compart-
•
ment if necessary.
Turn the pipe in the direction of the
•
cooking compartment (Fig. 5).
Open the water filling knob at the
•
desired position (hot-cold-both) (Fig.
4A) and fill the tank as needed.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
INSTRUCTIONS FOR USE
Close the knob/s when filling is com-
•
plete (Fig.4B).
Reposition the pipe so it does not
•
get in the way of the lid when it clo-
ses (Fig. 5).
SWITCHING ON/OFF / see SECT.
IMAGES - REF. m)
The appliance must be swi-
tched on after having filled the
cavity with water. Do not switch
it on when empty (see previous page).
The appliance must be swi-
tched on after having filled the
cooking compartment with wa-
ter. Do not switch it on when the co-
oking compartment is empty.
Left knob = left heating element
Right knob = right heating element
During operation, check the le-
vel of the water inside the co-
oking compartment and bring it
to the correct level as needed by
acting on the water filling knobs.
Having successfully performed the wa-
ter filling operations, proceed with the
"Switch On/Off" procedure as follows:
Turn the switch-on knob to "1-2-3"
•
as required. The green indicator light
will turn on signalling the operating
phase (Fig. 6 A).
Turn the knob to "Zero" (Fig. 6 B) to
•
switch the appliance off at the end of
the work cycle.
OPERATING CONTROL CAVITY /
see SECT. IMAGES - REF. n)
In the estimated models :
During operation, check the le-
vel of the water using the visual
display (Fig.8)
The pressure inside the cavity is
detected by the pressure gauge
placed on the valve (Fig. 7C). If
it exceeds kPa 50, the pressure relea-
se valve is activated automatically
(Fig. 7A).
- 16 -