The connection to the drain into the
system must be "OPEN, WITH NO
TRAP" and the material for pipe fit-
ting and containment must support
high temperatures of approximately
70°C in the appliance outlet area.
To perform a correct disposal of the
waters in the drainage system, make
sure there are no obstructions and
no type of hindrances on the whole
line length.
Check the correct inclination of the
device for grey water containment
and downflow. The device must let
the grey water easily drain away into
the system drain.
Increase the angle of incidence
(from 3° to 5° approximately) of
the drain into the system whene-
ver any backwater occurs.)
Connect an edge of the drain pipe to
the appliance connection;
Convey the opposite edge of the pipe
to the open drain (with no trap).
Make a visual check of the connection
seal and of the drain water downflow.
See schematic drawing (Fig. 5).

ELECTRICAL CONNECTION

Electrical connection should be per-
formed in compliance with the local
regulations in force, only by author-
ised and competent personnel.
the first instance, examine the data
shown on the technical data table of
this manual, on the serial plate and on
the electrical diagram.
Connect the equipment to an
overvoltage category III omnipo-
lar device.
EARTHING / It is essential to
earth the unit.To this purpose, it
is necessary to connect to an ef-
ficient earthing system the terminals
marked with the symbols placed on
the line-receiving terminal box. The
earthing system should comply with
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POWER SUPPLY CONNECTIONS
the local law in force.
SPECIFIC WARNINGS / The electrical
safety of this unit is assured only when
it is correctly connected to an efficient
earthing system as stated in the electri-
cal local safety regulations in force; the
Manufacturer declines any responsibi-
lity for the non-compliance with these
safety regulations.It is necessary to
verify this fundamental safety requisite
and, in case of doubt, ask for an accu-
rate testing of the system by professio-
nally qualifi ed personnel.The Manu-
facturer cannot be deemed responsible
for any damages caused by the lack of
unit earthing.
Never interrupt the earth wire
(Yellow-Green).
CONNECTION TO THE DIFFE-
RENT
TION NETWORKS / see SECT.
IMAGES - REF. e)
The equipment is delivered to work
with the voltage indicated on the
technical label attached on the ap-
pliance. Any other connection is to
be considered improper and therefo-
re dangerous.
It is mandatory to respect the
connection provided by the
manufacturer, visible on the con-
In
nection label near the terminal board.
It is forbidden to modify the
wiring inside the equipment
ELECTRICAL
THE CABLE TO THE TERMINAL
BOARD /
Connect the power cable to the termi-
nal board as described in: "Power sup-
ply connection" and indicated on the
connection plate. The diagram and the
table (see Technical data) indicate the
possible connections according to the
mains voltage.