Reactivation Outlet Ducting
The reactivation air should always be ducted to the
outside.
NOTICE: Temperatures inside React Out ducting
can reach 150°F (66°C). Use only appropriately
rated ducting.
Process Outlet Ducting
The process out air may be ducted where more fo-
cused drying is required. Use with layflat ducting only.
Maximum Ducting Length
To ensure maximum performance, do not exceed the-
se ducting lengths:
Reactivation air
Process air
Inlet air
For more ducting options, see Fig. C.
CONTROL PANEL
ON/OFF
DISPLAY MENU
MENU SELECTION /
UP KEY
WATER REMOVAL
20 ft.
6 m
|
10 ft.
3 m
|
30 ft.
9.1 m
|
When the machine is turned on, the display normally reads PLEASE WAIT
WARMING UP. Once the unit completes the warm-up procedure, the display
shows UNIT ON XXX HRS and cycles between INLET XXX°F and IN-
LET XX%.
Cycles through the display of additional dehumidifier conditions and User Set-
tings. To return to the main menu, press the ON/OFF key once.
Change system settings. The MENU SELECTION key acts as the "UP" key for
cycling through the setpoints.
Press and release to show a calculated amount of water removal in pints/day.
The unit will display WATER REMOVAL XXX PINTS/24H after 5 minutes of
run time. The display will automatically return to the "Unit On" display after a
few seconds.
NOTICE
Condensation may collect in the reactivation duct during opera-
tion. Do not allow water to run back into the unit. This could
cause a shock hazard or damage to the unit.
Press the
ON/OFF to turn the unit on.