Adjust the hut in the back of the equipment so you can assure the minimum tilt of 1 degree backwards.

4.3. Air Inlet/Outlet Installation

As the AquaPura Monobloc absorbs heat during its operation, the air flow (inlet/out-
let) must be directed to unheated areas. The equipment will cool the room where it is
placed and so if it is installed in heater rooms, the air flow must be directed to other
rooms and/or the outside.

4.3.1. Installation Without Ducts

The AquaPura Monobloc equipment must be installed in a place that is not too heated, and may be used
for dehumidifying and cooling these rooms (e.g., laundries, cellars, etc).
Distance between the top of the unit and the ceiling must be no less than 600mm (figura A).
If the distance between the unit and the ceiling is less than 600mm, two elbow-type joints must be in-
stalled as shown in the following picture (B/ C).
If equipment tilts other than back-
wards, this will cause condensates
to deposit in the tank.
WARNING
MONOBLOC 100L
41