5.5. Operating Modes

The AquaPura Monobloc is programmed to work in 3 running modes:
ECO on ECO mode functioning the equipment only functions as a heat pump to warm up the thermal
accumulator water. The functioning set point adopted corresponds to the SP1 parameter. While on ECO
functioning mode the compressor works alongside with the ventilator and the support resistance stays
always OFF.
NOTICE: On ECO mode we can have greater efficiency, allowing a bigger saving to the user.
AUTO on AUTO mode functioning the equipment functions as a heat pump plus resistance to warm up
the thermal accumulator water. The functioning set point adopted by the compressor and the resistance
corresponds to the parameter SP2.
While on AUTO functioning mode the compressor works alongside with the ventilator and the resistance.
ObSt on ObSt functioning mode the equipment functions as a heat pump plus resistance to warm up the
thermal accumulator water. O functioning set point adopted by the compressor and the resistance corre-
sponds to SP1 parameter.
While on ObSt functioning mode the compressor works alongside with the ventilator and the resistance.
NOTICE 1: The ObSt functioning mode longs a um cycle if the functioning mode before the changing was
ECO mode, in other words, after being activated and getting to the respective set point (SP1) it is auto-
matically cancelled and the equipment under takes by defect the functioning mode used before (ECO).
NOTICE 2: On ECO mode it is possible to activate the ObSt function when the thermal accumulator water
temperature is under SP3.
NOTICE 3: If the functioning mode ObSt is activated while the AUTO functioning mode is on the equipment
will function alternately between AUTO mode and ObSt mode, in other words, if the water temperature
decreases to be under the SP3 the controller assumes the ObSt function until getting to the set point SP2.
If the water temperature stays superior to SP3 the controller assumes AUTO mode.

5.6. Function "anti-legionella"

The Monobloc's electronic control features the disinfect function, which consists of a water heating cycle
up to 65 °C, for a period of time long enough to prevent the formation of germs inside the tank.
The function "antilegionella" is activated automatically after 30 days.

6. CHECKING GOOD RUNNING CONDITION

To check whether your equipment is running correctly, start it and wait at least 20-30 minutes and then
check these condition:
• The air temperature at the outlet of the evaporator should be lower 3 °C /4 °C when comparing with
the air temperature at the inlet.