Remote Control Linkage - Honda GCV530 Manual Del Propietário

Ocultar thumbs Ver también para GCV530:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
37Z0A6000.fm 14 ページ 2020年4月27日 月曜日 午後1時34分
Battery Connections for Electric Starter
Recommended Battery
12 V - 30 Ah
Be careful not to connect the battery in reverse polarity, as this will short
circuit the battery charging system. Always connect the positive (+)
battery cable to the battery terminal before connecting the negative (–)
battery cable, so your tools cannot cause a short circuit if they touch a
grounded part while tightening the positive (+) battery cable end.
A battery can explode if you do not follow the correct
procedure, seriously injuring anyone nearby.
Keep all sparks, open flames, and smoking materials away
from the battery.
The battery contains sulfuric acid (electrolyte), which is
highly corrosive and poisonous.
Getting electrolyte in your eyes or on your skin can cause
serious burns.
Wear protective clothing and eye protection when working
near the battery.
KEEP CHILDREN AWAY FROM THE BATTERY.
WARNING: Battery posts, terminals, and related accessories contain lead
and lead compounds. Wash your hands after handling.
1. Connect the battery positive (+) cable to the starter solenoid terminal
as shown.
2. Connect the battery negative (–) cable to an engine mounting bolt,
frame bolt, or other good engine ground connection.
3. Connect the battery positive (+) cable to the battery positive (+)
terminal as shown.
4. Connect the battery negative (–) cable to the battery negative (–)
terminal as shown.
5. Coat the terminals and cable ends with grease.
BATTERY
POSITIVE (+) CABLE
BATTERY
NEGATIVE (–) CABLE
14

Remote Control Linkage

The throttle and choke control levers are provided with holes for optional
cable attachment.
The following illustrations show installation examples for a solid wire
cable. Do not use a braided wire cable.
Single Lever Type:
CHOKE RETURN SPRING
INSTALLATION:
Install with the short end
hook toward the control
base side.
CONTROL LEVER
Dual Lever Type:
CHOKE RETURN SPRING
INSTALLATION:
Install with the short end
hook toward the control
base side.
CHOKE LEVER
STARTER
SOLENOID
ENGLISH
THROTTLE/CHOKE
CABLE (SOLID WIRE)
5×16 mm SCREW
CABLE HOLDER
STOPPER RUBBER
INSTALLATION:
To install the stopper
rubber, first align the boss
with the hole of the
control lever bracket, then
turn the rubber 90° and
secure it to the bracket as
shown.
LEVER SPRING
THROTTLE CABLE
(SOLID WIRE)
5×16 mm SCREW (2)
CABLE HOLDER (2)
CHOKE CABLE
(SOLID WIRE)
THROTTLE LEVER

Publicidad

Tabla de contenido
loading

Tabla de contenido