Models And Products Description; Description; Typical Installation; Technical Specifications - Comunello Automation RAMPART 600 Instrucciones De Uso Y De Instalacion

Ocultar thumbs Ver también para RAMPART 600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

leakage of harmful substances.
• Connect the control unit exclusively to an electric power supply line equipped with an efficient protective earth conductor.
• Any operations that require the housing of RAMPART to be opened must be performed with the control unit disconnected from
the electrical power supply; if the disconnect device is not clearly visible from where you are working, attach a warning notice to
the effect: "WARNING - MAINTENANCE IN PROGRESS".
• In the case of tripping of circuit breakers or blowing of fuses, find the fault and remedy it before resetting the circuit breaker or
changing the fuse.
• If the fault cannot be remedied using the information given in this manual, consult technical service.
• The device can't be used by children younger than 8 years of age and by people with reduced physical, sensory or mental
capabilities, or without experience or the required knowledge if not under surveillance or after having received instructions about
the safe use of the device and the inherent risks in it. Children should not play with the device. Cleaning and maintenance should
not be carried out by children without surveillance.
• Children can't play with the commands of the automatism. Remote controls should be kept out of reach of children. It is suggested
to periodically examine the installation in order to verify the presence of possible damages to the cables, springs and mechanical
parts. Automation should not be used if it is necessary a repair intervention.

2 MODELS AND PRODUCTS DESCRIPTION

2.1 DESCRIPTION

Electromechanical operator for spring balanced sectional doors. Operator designed for coupling to tracks with a drive belt or chain,
built-in electronic control unit with electronic limit stops (encoder) for 24V

2.2 TYPICAL INSTALLATION

C
D
B
KEY
A OPERATOR WITH BUILT-IN CONTROL UNIT
B CLOSING PHOTOCELLS
C FLASHING LIGHT
D KEY SELECTOR SWITCH

3 TECHNICAL SPECIFICATIONS

Power
Maximum pulling effort (force needed to start door move)
Nominal pulling effort (force needed to maintain door move)
Maximum door leaf weight
Maximum opening speed
Speed during nominal effort
Maximum continuous motortime
Power consumption during nominal effort
Light time (LED-time) after movement stop
Current consumption of additional (external devices)
Current consumption of external signal Lamp
Radiocontrol
Protection type
Protection class
Temperature range
Drive weight (net)
20
COMUNELLO ®Copyright 2021 - All rights reserved
A
RAMPART 600
RAMPART 1000
230V (±10%) / 50Hz
600N
1000N
200N
300N
110kg
210kg
0,14 meters/seconds
0,1 meters/seconds
60 seconds (intermittent operation mode)
110 W
150 W
30 seconds after opening the door
1 minute after closing the door
24V DC / max. 8W (max 300mA)
24V DC / max. 5W (max 200mA)
433,92MHz / dynamic code
200 remotes max
II
IP20
-20°C / +50°C
4,5kg
5,0kg
motor, plug-in radio receiver: 433.92 MHz narrowband.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rampart 1000

Tabla de contenido