Balluff BTL7-A/C/E/G5-M-J-DEXC-TA12 Serie Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 143
Certificate:
2411253
Project:
70099158
BTLx-Tcj0-Mm-J-DEXC- *-TA12
BTLx-Hckl-Mm-J-DEXC- *-TA12
BTL7-Vcqr-Mm-J-DEXC-*-TA12
x = 5 or 7
Q = Quadrature output
S = SSI output
T = Profibus DP output
H = CANopen output
V = EtherCAT output
a = Digital pulse output: I, K, L, M, N, P or R.
b = Analog output: A, B, C, E or G.
c = Supply voltage: 1 or 5.
d = Analog output signal characteristic: 0, 1 or 7.
e = Quadrature output signal frequency: 0, 1, 2 or 6.
f = Quadrature output resolution: 0, 1, 2, 3, 5, 6, 7 or 8.
g = Quadrature output mode/update rate: 0, 1, 2 or 4.
h = SSI output signal type, resolution and mode: Any alpha/numeric code (up to 3 digits) not effecting the
Explosionproof protection method)
i = BTL7 P/M Interface without DPI/IP interface: 10. BTL7 P/M Interface with DPI/IP interface: 11.
Blank for BTL5.
j = Profibus output software configuration: 1, 2 or 3.
k = CANbus output software configuration: 1, 2 or 3.
l = CANbus output baud rate: 0, 1, 2, 3, 4, 5, 6, 7 or 8.
m = Stroke length in millimeters (Maximums: BTL5 = 5080 & BTL7 = 7620)
n = Interrogation method (if a = "R", otherwise blank): E or I.
o = Recirculation count (if a = "R", otherwise blank): 1 to 16.
q = Number of magnets or address setting (Any alpha/numeric code not effecting the Explosionproof
protection method)
r = Protocol type (Any alpha/numeric code not effecting the Explosionproof protection method)
* = S or M = Special electrical or internal mechanical modifications not affecting scheduled drawings or
the Explosion-proof/Flame-proof Protection methods and not exceeding 3W for the BTL5 and
5W for the BTL7. (may also be left blank)
Note: The IP68 rating includes a submersion rating of 167ft (51m) for 48 hours.
APPLICABLE REQUIREMENTS
CAN/CSA Standard C22.2 No. 0-10
CSA C22.2 No. 25-M1966
CSA C22.2 No. 30-M1986
CSA C22.2 No. 94.1-07
CSA C22.2 No. 94.2-07
DQD 507 Rev. 2016-02-18
General Requirements - Canadian Electrical Code, Part II
Enclosures for Use in Class II, Groups E, F, and G Hazardous Locations
Explosion-Proof Enclosures for Use in Class I Hazardous Locations -
Industrial Products
Enclosures for Electrical Equipment, Non-Environmental Considerations
Enclosures for Electrical Equipment, Environmental Considerations
Page 2
Master Contract: 252588
Date Issued: 2016-11-23

Publicidad

Tabla de contenido