Ambient Conditions; Supply Voltage (External); Btl7-A; Btl7-C - Balluff BTL7-A/C/E/G5-M-J-DEXC-TA12 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 143
BTL7-A/C/E/G5_ _-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
11
Technical data
11.1
Accuracy
The specifications are typical values at DC 24 V and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S or
BTL-P-1012-4R magnet or with the BTL2-S-6216-8P-Ex,
BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or
BTL2-S-4414-4Z01-Ex float.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply. Special versions are indicated by the
suffix -SA on the part label.
Repeat accuracy
Voltage, typical
Current, typical
Sampling rate
Dependent on nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 to
≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
1)
Max. detectable velocity
11.2

Ambient conditions

Operating temperature
Standard
2)
Extended
3)
, SA418
Storage temperature
Humidity
Rod pressure rating (when
installed in hydraulic cylinders)
Shock rating
Continuous shock
4), 5)
per EN 60068-2-27
Vibration
4), 5)
per EN 60068-2-6
Degree of protection per
IEC 60529
26
english
±10 µm
±5 µm
250 µs...5.7 ms
500 µs
±50 µm
±0.01% FS
±0.02% FS
≤ 30 ppm/K
10 m/s
–40 °C...+80 °C
–50°C...+80°C
–50°C...+85°C
< 90%, non-condensing
≤ 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10...2000 Hz
4), 6)
IP68
Ignition protection "d"
Flameproof enclosure
11.3

Supply voltage (external)

Voltage, stabilized:
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
7)
Overvoltage protection
Dielectric strength
(GND to housing)
11.4
Output
BTL7-A... Output voltage
Load current
BTL7-C... Output current
Load resistance
BTL7-E... Output current
Load resistance
BTL7-G... Output voltage
Load current
Short-circuit resistance
11.5
Input
Programming inputs La, Lb:
Overvoltage protection
1) Nominal length = 500 mm, magnet in the middle of the measuring range
2) See approvals on page 6
3) Prerequisite: Nominal length ≤ 2680 mm.
The device must be activated at ≥ –40 °C.
4) Individual specifications as per Balluff factory standard
5) Resonant frequencies excluded
6) To maintain the IP68 rating, ensure that the connection at the conduit
opening also meets this standard. Thread sealant should be used on the
conduit opening to ensure protection against moisture ingress. Take
measures to prevent the possibility of internal condensation at the
conduit opening from entering the BTL.
7) A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
Ensure power is limited to ≤ 5 W!
10...30 V DC
≤ 0.5 V
ss
≤ 150 mA
≤ 500 mA
Up to 36 V
Up to 36 V
500 V AC
0...10 V and 10...0 V
≤ 5 mA
0...20 mA/20...0 mA
≤ 500 Ω
4...20 mA/20...4 mA
≤ 500 Ω
10...10 V and 10...
0 V
–1
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active, 10 to
30 V DC
Up to 36 V

Publicidad

Tabla de contenido
loading

Tabla de contenido